Miele TX2070 작동 및 설치 지침 - 페이지 33
{카테고리_이름} Miele TX2070에 대한 작동 및 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Miele TX2070 44 페이지.
ab The shaded area represents the wall or ceiling area for the vent cut-out, for
fitting the connection socket and on EXT models for feeding the connection
cable through to the external motor.
Connection for air extraction 150 mm, or 125 mm with reducing collar.
Safety distance between hob and cooker hood (S)
An insufficient safety distance between the hob and the cooker hood can result
in damage to the cooker hood.
The safety distance between the top of a cooker or hob and the bottom of the
cooker hood canopy must measure at least 365 mm, unless a greater distance
is specified by the manufacturer of your cooking appliance.
For installation above gas hobs, the following outputs must not be exceeded:
- multi-burner gas hobs total output > 21.6 kW, or where one burner > 4.8 kW.
- single burner gas hob output > 8.1 kW
See "Warning and Safety instructions" for further information.
Installation
33