Technical Specifications
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power Supply
Power Supply
Power Supply
Type
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Range
Rated Input Current
Rated Input Current with
Energy
Efficient*
Power
Supply
Current Leakage
(NFPA 99)
System Heat Dissipation
FEMP Standby Power
Compliant
(<2W in S5 – Power Off)*
Power Consumption in ES
Mode – Suspend to RAM (S3)
(Instantly Available PC)
Dimensions
Total Cord Length
Non-operating: –22° to 140° F(–30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
135W 87% efficient
active PFC
90 – 264 VAC
100 – 240 VAC
50/60 Hz
47 – 63 Hz
N/A
2.4A
< 250 µA
Typical 133 btu/hr
(33.5 kg-cal/hr)
Maximum 549 btu/hr
(132 kg-cal/hr)
X
< 2.7W
6.7 x 2.6 x 1.5 in
12 ft 8 in
DA - 13528
North America — Version 9 — April 11, 2011
HP Compaq 8000f Elite USDT PC
HP Compaq 8000f Elite USDT PC
HP Compaq 8000f Elite USDT PC
HP Compaq 8000f Elite USDT PC
Operating: 50° to 95° F (10° to 35°
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
C)*