S2 Canister Vacuums
4.4
Motor Protection Filter Frame Removal
1. Open the casing top wide.
2. Remove the bag.
3. Release the frame retaining tabs with a suitable tool; see Figure 020-6,
Item 1.
4. Remove the frame.
Note:
If it is too difficult to release the tabs from the top, open the frame, insert the
flathead screwdriver behind it and pry it out.
Figure 020-6: Filter Frame Retaining Tabs
Note:
When re-installing, insert the top of the frame first.
4.5
Cover Frame Removal
1. Remove the casing top. See Section 020-4.3.
2. Remove the exhaust filter.
3. Remove the cap. See Section 030-4.1.
4. Release the electronic retainer, Figure 010-3, Item 1, and tilt it upwards,
Figure 010-3, Item 2.
5. Remove the bag holder; see Section 020-4.1.
6. Remove the six cover frame retaining screws (T20); see Figure 020-7,
Item 1.