Converting CS 1011
To convert the burner
,
Conversion to a different type of
gas should only be performed by an
authorized gas technician.
Turn off the main gas supply (if the
appliance has been installed) and
disconnect the appliance from the
main electrical power supply before
proceeding.
When converting to a different type of
gas, the jets and needle valves have to
be changed.
Maximum output
Gas type
Natural Gas
LP Gas (Propane)
Minimum output
Gas type
Natural Gas
LP Gas (Propane)
4
BTU/hr
kW
17,500
5.2
17,500
5.2
BTU/hr
kW
680
0.20
680
0.20
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Code Jet size
Natural gas
Outer/Large
200
burner
Inner/Small
34
burner
LP Gas (Propane)
Outer/Large
120
burner
Inner/Small
7
burner
Code
Needle
(Ø mm)
valve
size
(Ø mm)
2.00
88
0.88
34
42
0.42
1.20
54
0.54
7
25
0.25