Allnet ALL-SGO8103P 사용자 설명서 - 페이지 7

{카테고리_이름} Allnet ALL-SGO8103P에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Allnet ALL-SGO8103P 9 페이지.

Allnet ALL-SGO8103P 사용자 설명서

Connecting Fiber Optic Cable

Connect "SFP" jack (input) to the remote Ethernet network and
"PoE" jack (output) to the terminal.
Verify connection to main AC power.
Tip
For easier installation, start port number 1 assembly (PoE 1) first and
keep the SFP port to be connected last.
Note For non AF/AT compliant unit - use a splitter; ensure splitter is
connected close to the terminal and not on the Switch.

Safety Information

Installation and removal of the ALL-SGO8103P must be carried out
by qualified personnel only.
The ALL-SGO8103P "PoE" ports are shielded RJ45 data sockets. They
cannot be used as Plain Old Telephone Service (POTS) sockets. Only
RJ45 data connectors can be connected to these sockets.
Follow basic electricity safety measures whenever connecting the
ALL-SGO8103P to its power source.
A voltage mismatch can cause equipment damage and may pose a
fire hazard. If the voltage indicated on the label is different from
the power outlet voltage, do not connect the ALL-SGO8103P to this
power outlet!
All wiring and connections shall be in accordance with NFPA 70
(NEC)
This product is not intended to become a permanent part of the
building structure.
Power supply cord must not be attached to the building
surface or run through walls, ceilings, floors and similar
openings in the building structure.
© ALLNET GmbH Computersysteme 2022– All rights reserved
Errors and changes reserved