Miele KM 363 G 설치 지침 매뉴얼
Conversion to another type of gas

After changing the jets

^ Assemble the removed burner parts
in reverse order and check for leaks
by operating the burner without the
upper section of the hob in place
(use a match to ignite the flame).
^ Remove the burner parts again.
^ Then replace the upper section of the
hob.
KM 360 G / KM 362 G
When replacing the stainless steel
upper section:
Position the upper section as shown in
the illustration, pushing it forwards first
of all and then backwards until the
angle bracket a clicks into place
underneath the lip b of the lower
section. Then lower the upper section.
a
b
22
^ Screw in the burner bases and
re-assemble the burner parts, making
sure they are in the correct order.
^ Replace the controls.
^ Finally ignite all the burners to check
that they are operating correctly.
The flame must not go out in the lowest
setting, or when the control is turned
quickly from a high to a low setting.
In the highest setting the flame must
have a distinctive and visible core.
Stick the label supplied with the jets
above the label stating the type of
gas being used.