DIAL PEC-A-1300-1M 사용자 설명서 - 페이지 8

{카테고리_이름} DIAL PEC-A-1300-1M에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DIAL PEC-A-1300-1M 11 페이지. Portable evaporative cooler

DIAL PEC-A-1300-1M 사용자 설명서

MAINTENANCE

CLEANING
CAUTION: Turn off the evaporative cooler and disconnect the plug from the electrical outlet
before cleaning, servicing or performing any maintenance on the unit.
CLEANING THE EXTERIOR SURFACE OF THE EVAPORATIVE COOLER
• Clean the plastic housing with a duster or a soft moist cloth.
• Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible
damage.
• Use care when cleaning around the control switch; make sure no water enters near the control switch.
The warranty does not cover damage caused by water.
CLEANING THE RESERVOIR
• Unscrew and remove the Back Panel to access the Reservoir.
• Empty the Reservoir.
• Use a cloth (dipped in mild detergent solution) to wipe the Reservoir and rinse it with water.
• Cleaning the Reservoir at least once a week will help reduce any mineral deposits and keep the filters
clean.
• Do not run the unit in cooling mode with stale water in the Reservoir.
• Empty the Reservoir and refill it with fresh water if water has been left in the Reservoir for an
extended period.
MAINTAINING AND CHANGING THE RIGID MEDIA PADS
The frequency of cleaning the Rigid Media Pad depends on local air and water conditions. In areas where
the mineral content of the water is high (hard water), mineral deposits may build up on the media pad and
restrict air flow. If mineral deposits remain on the media pad, it should be removed and washed under
fresh water or replaced. We recommend cleaning the media pad at least every two months, depending on
water conditions.
For best results, allow the media pad to dry after each use by turning off the pump and running the
unit in one of the fan only speeds for up to 15 minutes before turning off the unit.
Go to www.dialmfg.com/pec/technical-data for detailed instructions on removing and replacing Rigid
Media Pad.
END OF SEASON MAINTENANCE
1. Empty the Reservoir and wipe it with warm soapy water.
2. Dry the Reservoir and clean the Honeycomb pad.
3. Keep the unit in a dry place.