max. 1 Nm
Seal
Note the voltage and current type as specified on the type
label.
Procedure:
Tighten cable plug (for permitted types see data sheet), observing
max. torque 1 Nm.
Check that seal is fitted correctly.
Connect protective conductor and check electrical continuity
between coil and body.
Authorized cable plug e.g.
Type 2508 or other suitable
cable plug in accordance with
DIN EN 175301-803 Form A
6.5.1 Electrical connection - Pulse
4
2
3
1
The connection terminals in the cable plug are identified with
the numbers 1 to 3 according to the terminals on the valve.
Procedure:
Connect the pulse valves (variable code CF 02).
For direct current versions connect negative terminal to terminal 3.
DC connections:
Terminal 1 = closed +
Terminal 2 = open +
Terminal 3 = GND -
Protective conductor
connection