Dialog DA16200 사용자 설명서 - 페이지 10
{카테고리_이름} Dialog DA16200에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dialog DA16200 20 페이지. At gui tool
DA16200 AT GUI Tool
●
Check TX Setting parameters and click the Mode Select button. Confirm message will be shown
as
Figure 10.
This is a normal state
●
Have to select Data Rate, Channel, and Power as you want to test.
○
Packet mode: Normal test mode with packet generation mode. We can adjust duty of RF
Burst at time domain in this mode.
○
Cont mode: Continuous TX out mode.
○
This mode is for TX power test and etc.
○
In this mode, TX packet is generated continuously over 95% duty cycle.
○
CW mode: Only single sinewave tone out mode. This mode is for freq err check.
○
Data Rate: Choose modulation type to test.
○
Power: Select or tune the power level. ("0" step is Maximum)
○
The difference between power steps is about 0.8~1dB/1step
○
Size: You can adjust duty rate with this number. However, it is not linear as the number, so it
needs to check with equipment like spectrum analyzer to set exactly. (Equipment setting is to
zero span setting or burst mode setting)
●
TX packet generation
○
Use the Start TX button and the Stop TX button.
○
When you want to change for another condition, you should click "Stop TX" before starting
new test.
User Manual
CFR0012
Figure 10: Debug Console - Tx mode
Revision 1.0 DRAFT
10 of 20
03-Jul-2019
© 2020 Dialog Semiconductor