3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
3-2. Specifications*
Coolant Tank
Capacity
Model
Hydracool 1
8 L
8 L
Hydracool 2
8 L
8 L
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40°C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.
3-3. Coolant Specifications
Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).
3-4. Environmental Specifications
A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
This equipment is designed for outdoor use. It may be stored, but is not intended to be used outside during precipitation unless sheltered.
SECTION 3 − SPECIFICATIONS
Maximum Cooling
Capacity
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32
Aluminum Protecting Coolant 043809*
°
°
F (-38
C) and resist algae growth.
Hydracool 1 − IP21
Hydracool 2 − IP23
Input Power
Cord with
Input Power
Plug
Single Phase
2 m
115 VAC
50/60 Hz
2.5 Amperes
Single Phase
2 m**
230 VAC
50/60 Hz
1.3 Amperes
Single Phase
2 m
115 VAC
50/60 Hz
2.5 Amperes
Single Phase
2 m**
230 VAC
50/60 Hz
1.3 Amperes
IP Rating
IP Rating
Dimensions
Length: 305 mm
Height: 674 mm
Width: 263 mm
Length: 305 mm
Height: 674 mm
Width: 263 mm
Length: 585 mm
Height: 286 mm
Width: 324 mm
Length: 585 mm
Height: 286 mm
Width: 324 mm
Coolant
°
°
F (0
C)
°
°
F (0
C)
OM-254203 Page 5
Weight
20.7 kg
20.7 kg
20.8 kg