Miller Auto Deltaweld 452 소유자 매뉴얼 - 페이지 22

{카테고리_이름} Miller Auto Deltaweld 452에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller Auto Deltaweld 452 42 페이지. 60 hz, 50/60 hz arc welding power source
Miller Auto Deltaweld 452에 대해서도 마찬가지입니다: 소유자 매뉴얼 (30 페이지), 소유자 매뉴얼 (40 페이지)

Miller Auto Deltaweld 452 소유자 매뉴얼

4-9. Remote 14 Receptacle RC8

4-10. Remote 14 Receptacle RC8 Information

24 VOLTS AC
24 VOLTS AC
REMOTE OUTPUT CONTROL
115 VOLTS AC
115 VOLTS AC
GND
REMOTE POWER ON/OFF
REMOTE POWER ON/OFF
REMOTE VOLTAGE SENSING
REMOTE VOLTAGE SENSING
* Not Used
OM-223 Page 18
1
A
J
K
I
B
C L N
H
M
D
G
F
E
Socket
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac contactor control circuit.
C
Command reference; 0 to +10 volts dc.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
F
Current feedback; 1 volt per 100 amperes.
H
Voltage feedback; 1 volt per 10 arc volts.
I
115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac contactor control circuit.
K
Chassis common.
G
Circuit common for 24 and 115 volts ac circuits.
To remote On/Off switch.
To remote On/Off switch.
*
*
Voltage sensing signal from Negative (−) weld output terminal.
*
Voltage sensing signal from Positive (+) weld output terminal.
Return To Table Of Contents
Y Turn off power before con-
necting to receptacle.
1
Remote 14 Receptacle RC8
Connect feeder to RC8.
Ref. ST-800 166-D / Ref. S-0004-A
Information