Miller Axcess 675 소유자 매뉴얼 - 페이지 33
{카테고리_이름} Miller Axcess 675에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller Axcess 675 48 페이지. Automatic welding interface and arc welding power source
Miller Axcess 675에 대해서도 마찬가지입니다: 소유자 매뉴얼 (48 페이지)
SECTION 9 − TROUBLESHOOTING
9-1. Removing Cover and Measuring Input Capacitor Voltage
+ lead to left bus terminal, − lead to right
bus terminal
+ lead to left bus terminal, − lead to right
bus terminal
+ lead to left bus terminal, − lead to right
Tools Needed:
1
2
1
2
1
bus terminal
5/16 in.
2
3
Typical Bleeder
Resistor
25 to 1000 ohm, 5 watt resistor
#16 AWG 1000 volts dc
insulation rating, approx
3 in (76 mm) leads
!
Turn Off welding power
source, and disconnect in-
put power.
!
Significant DC voltage can
remain on capacitors after
unit is Off. Always check the
voltage as shown to be sure
the input capacitors have
discharged before working
on unit.
Remove cover
1
Power Interconnect Board
PC2
2
Voltmeter
Measure the DC voltage across the
+ bus terminal and − bus terminal on
PC2 as shown until voltage drops to
near 0 (zero) volts. Measure input
capacitor voltage on all three
inverter
assemblies
before
proceeding.
3
Typical Bleeder Resistor
An example of a typical bleeder
resistor is shown on this page.
Proceed with job inside unit.
Reinstall cover when finished.
802 985 / Ref. 803 825-A
OM-217 751 Page 29