Miller BOBCAT 225G PLUS 소유자 매뉴얼 - 페이지 17

{카테고리_이름} Miller BOBCAT 225G PLUS에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller BOBCAT 225G PLUS 40 페이지.

SECTION 5 – OPERATING AUXILIARY EQUIPMENT

5-1. Standard Receptacles

6
3
SIMULTANEOUS WELDING AND POWER
Weld Current
In Amperes
210
140
90
See Owner's Manual for additional information.
4
WITH FINE ADJUST SET AT 10
120V
Total Power
Receptacle
In Watts
Amperes
1000
8
4300
36
6000
50
5
2
1
7
240V
Receptacle
Amperes
4
18
25
S-166 360-A
Y If unit does not have GFCI re-
ceptacles,
use
GFCI-
protected extension cord.
.
Auxiliary power decreases as
weld current increases.
Set Fine Adjust control R1 at 10
for full auxiliary power.
1
120 V 15 A AC Duplex
Receptacle RC3
2
120 V 15 A AC Duplex
Receptacle RC2
RC3 and RC2 supply 60 Hz single-
phase power at weld/power speed.
Maximum output from RC3 or RC2
is 2.4 kVA/kW. (CSA : 1.8 kVA/kW).
3
240 V 50 A AC Receptacle
RC1
RC1 supplies 60 Hz single-phase
power
at
weld/power
speed.
Maximum output is 8 kVA/kW.
4
Circuit Breaker CB3
5
Circuit Breaker CB4
CB3 protects RC2 and CB4
protects RC3 from overload. If a cir-
cuit breaker opens, the receptacle
does not work.
6
Circuit Breakers CB1 And
CB2
CB1 and CB2 protect RC1 from
overload. If CB1 or CB2 opens,
RC1 and one of the 120 volt
receptacles does not work. 120
volts may still be present at RC1.
.
If circuit breaker continues to
open,
contact
Factory
Authorized Service Agent.
Combined output of all receptacles
limited to 8 kVA/kW rating of the
generator.
EXAMPLE: If 20 A is drawn from
each 120 V duplex receptacle, only
13 A is available at the 240V
receptacle:
2 x (120 V x 20 A) + (240 V x 13 A)
= 7.9 kVA/kW
7
Auxiliary Power While
Welding Label
Ref. ST-178 079-A
OM-403 Page 13