4-5. Amperage Control

4-6. Remote 14 Receptacle Information

This unit automatically senses when a remote control is connected to the remote 14 receptacle. After connecting a
remote control, the unit will automatically adjust output control to a primary/secondary configuration. In this
configuration, the AMP ADJUST control on the unit becomes the primary and sets the maximum amperage output of
the unit. The remote control becomes the secondary and provides an amperage range adjustment of 0 to 100% based
on the AMP ADJUST control setting.
A
J
K
K
I
I
B
B
C L N
H
M
M
D
D
G
G
F
E
*The remaining sockets are not used.

4-7. Fan-On-Demand

This unit is equipped with Fan-On-Demand. The fan operates only when necessary to cool internal components. At
power down, the fan will operate for a short period of time while the output indicator light is flashing.

4-8. Rack Mounting

This unit is capable of being rack mounted see rack Owner's Manual, OM-221 611.
OM-217 655 Page 26
15 VOLTS DC
15 VOLTS DC
REMOTE
OUTPUT
CONTROL
CONTROL
GND
803 942-A
1
AMP ADJUST (Amperage
Control)
1
Rotate knob clockwise to increase
amperage (5-280 amps).
Socket*
Socket Information
A
15 volts dc (not functional).
B
Contact closure to A completes 15 volts dc
contactor control circuit (not functional).
C
Output to remote control; 0 to +10 volts dc.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control.
K
Chassis common.