Miller Dimension NT 450 소유자 매뉴얼 - 페이지 19

{카테고리_이름} Miller Dimension NT 450에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller Dimension NT 450 40 페이지.

5-1. Selecting A Location

Movement
Location
SECTION 5 − INSTALLATION
1
OR
18 in.
(460 mm)
.
A complete Parts List is available at www.MillerWelds.com
!
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
1
Lifting Eye
2
Lifting Forks
Use lifting eye or lifting forks to
move unit.
If using lifting forks, extend forks
beyond opposite side of unit.
3
Line Disconnect Device
Locate unit near correct input pow-
er supply.
2
3
18 in.
(460 mm)
OM-2252 Page 15