Miller Gold Seal 160 i 소유자 매뉴얼 - 페이지 12

{카테고리_이름} Miller Gold Seal 160 i에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller Gold Seal 160 i 28 페이지. Arc welding power source

Miller Gold Seal 160 i 소유자 매뉴얼

2-7. Weld Output Terminals And Selecting Cable Sizes

Turn Off power before
connecting to weld output
receptacles.
Negative
Positive
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

2-8. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Reference: 1997 National Electrical Code (NEC)
OM-189 116 Page 8
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
10 – 60%
Welding
60 – 100%
Duty
Amperes
Duty Cycle
Cycle
100
4
150
3
200
3
250
2
150 ft
200 ft
(45 m)
(60 m)
4
4
3
3
2
1
2
1
1/0
1
1/0
2/0
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 – 100% Duty Cycle
2
1
1/0
1/0
2/0
3/0
2/0
3/0
4/0
3/0
4/0
2-2/0
230
18
30
400 ft
(120 m)
1/0
3/0
4/0
2-2/0
S-0007-D
240
17
30
S-0092-J