Miller Syncrowave 351 소유자 매뉴얼 - 페이지 19

{카테고리_이름} Miller Syncrowave 351에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller Syncrowave 351 42 페이지. Arc welding power source

3-7. Remote 14 Receptacle

A
J
K
I
B
C L N
H
M
D
G
F
E
ST-149 842-E
*The remaining sockets are not used.

3-8. 115 Volts AC Duplex Receptacle And Shielding Gas Connections

1
Socket*
A
B
C
D
A
E
K
5
6
3
2
Socket Information
24 volts ac.
Contact closure to A completes 24 volts ac contactor control circuit.
Command reference; 0 to +10 volts dc output to remote control.
Remote control circuit common.
0 to +10 volts dc input command signal from remote control.
Chassis common.
Y Turn Off power before con-
1
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 5-2).
4
2
3
Fittings have 5/8-18 right-hand
threads.
4
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5
6
Typical flow rate is 20 cfh (cubic feet
per hour).
necting to receptacle.
115 V AC Receptacle
Gas Valve In Fitting
Gas Valve Out Fitting
Cylinder Valve
Regulator/Flow Gauge
Flow Adjust
Ref. ST-154 795-B / Ref. ST-149 842-E
TM-354 Page 15