Miller XMT 456 CC/CV 소유자 매뉴얼 - 페이지 17

{카테고리_이름} Miller XMT 456 CC/CV에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller XMT 456 CC/CV 40 페이지.

Miller XMT 456 CC/CV 소유자 매뉴얼

3-7. Connecting Weld Output Cables

Tools Needed:
3/4 in (19 mm)
Y Turn off power before connecting to
weld output terminals.
Y Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.

3-8. Remote 14 Receptacle Information

A
J
K
K
I
I
B
B
C L N
H
M
M
D
D
G
G
F
E
*The remaining sockets are not used.
4
1
Do not place
anything between
weld cable terminal
and copper bar.
2
3
Correct Installation
1
Weld Output Terminal
2
Supplied Weld Output Terminal Nut
3
Weld Cable Terminal
4
Copper Bar
Remove supplied nut from weld output ter-
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
Ref. ST-801 718
REMOTE
REMOTE
CONTROL
A/V
AMPERAGE
AMPERAGE
VOLTAGE
GND
GND
Incorrect Installation
minal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
Socket*
Socket Information
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
C
Output to remote control; +10 volts dc in MIG
mode. For XMT 456 only: 0 to +10 volts dc in oth-
er modes.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from re-
mote control.
M
Mode select.
N
Remote inductance control.
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 arc volts.
G
Circuit common for 24 and 115 volts ac circuits.
K
Chassis common.
803 778-A
OM-2232 Page 13