{카테고리_이름} Miller AID115GBR에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller AID115GBR 24 페이지. Wire feeder

3-6. Plug Connections

2

3-7. Threading And Feeding Welding Wire

Tools Needed:
Pressure
Adjust
JOG
Push wire thru guide up to drive rolls; continue to
hold welding wire. Press power source Jog push
button until drive rolls grab wire. Adjust tension until
wire does not slip. Indicator is for reference only.
OM-221 785 Page 12
1
3
Welding Power Source
ON
PURGE
V
OFF
JOG
POWER
Turn on power at welding power source.
Pressure
Adjust
Press Jog push button until wire comes
out of gun. Feed wire to check drive roll
pressure. Adjust knob enough to pre-
vent slipping.
1
2
Cord is available in 20 ft (6.1 m),
30 ft (9.1 m) or 50 ft (15.2 m)
lengths.
3
To make connections, align key-
way, insert plug, and tighten
threaded collar.
Hold wire tightly to keep it
from unraveling.
Pull and hold wire; cut off end.
WOOD
Ref. 804 391-A / Ref. 156 798 / 802 914
Weld Control
Motor Control Cord (Not
Supplied)
Motor/Drive Assembly
Ref. 804 104-C
6 in
(150 mm)
Cut off wire. Close cover.