4-7. Electrical Service Guide For 230 VAC

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose − no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).

4-8. Extension Cord Data

NOTE
Input Power
Phase
Input Voltage
115 V
1
230 V
1
OM-1328 Page 14
Circuit Breaker
When calculating max. cord length, remember to include conductor length from
line disconnect device to input power receptacle.
Hertz
60
60
1
2
, Time-Delay
3
Normal Operating
Conductor Size
14 AWG
14 AWG
230
20
20
25
14
67
(20)
14
Max. Cord Length
23 ft (7 m)
67 ft (20 m)