Miller 819A 기술 매뉴얼 - 페이지 16
{카테고리_이름} Miller 819A에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Miller 819A 44 페이지.
8-2. Troubleshooting Circuit Diagram For Welding Generator
I2 = 1 amps DC (60 Hz)
No greater than 3.5 amps
DC under load
V13
Ridge denotes Pin 1
TM-268 819 Page 14
RC31
See Section 8-4
for PC1 data
I2
V12
Pin 5 - Circuit Common
PLG1
.
Voltage readings taken with
PLG1 connected to RC1 on PC2.
.
Voltage readings taken with PLG31
connected to RC31 on PC1.
PLG31
V10
I1 = 1 amps DC (60 Hz)
No greater than 3.5 amps
DC under load
See Section 8-6
for PC2 data
Ridge denotes Pin 1
V11
Pin 7 Circuit Common
I1
RC1
Belt Driven Generator