2-8. Weld Output Terminals and Selecting Cable Sizes
NOTE
Weld Output
Terminals
Y Turn Off welding pow-
er source and disconnect
input power before con-
necting to weld output ter-
minals.
Electrode
Work
Weld Output
Weld Output
Terminals
Terminals
Requires cable lugs with
5/8 in diameter holes.
15/16 in
15/16 in
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your
2
distributor for the mm
equivalent weld cable sizes.
In the table below, when multiple numbers are indicated separated by a hyphen,
the number to the left of the hyphen indicates how many cables are to be used, and
the number to the right indicates the size of the cable to be used. For example,
3-3/0 indicates that 3 cables of 3/0 gauge need to be used for electrode and work
connections.
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
Welding
10 – 60%
60 – 100%
Amperes
Duty Cycle
Duty Cycle
100
4
150
3
200
3
250
2
300
1
350
1/0
400
1/0
500
2/0
600
3/0
700
4/0
800
4/0
900
2-2/0
1000
2-2/0
1250
2-3/0
150 ft
200 ft
(45 m)
(60 m)
4
4
3
3
2
1
2
1
1/0
1
1/0
2/0
1/0
2/0
3/0
2/0
3/0
4/0
2/0
3/0
4/0
3/0
4/0
2-2/0
4/0
2-2/0
2-3/0
2-2/0
2-3/0
2-4/0
2-2/0
2-3/0
2-4/0
2-3/0
2-4/0
3-3/0
2-3/0
2-4/0
3-3/0
2-4/0
3-3/0
4-3/0
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 – 100% Duty Cycle
2
1
1/0
1/0
2/0
3/0
2/0
3/0
4/0
3/0
4/0
2-2/0
4/0
2-2/0
2-3/0
2-2/0
2-3/0
2-3/0
2-2/0
2-3/0
2-4/0
2-3/0
2-4/0
3-3/0
2-4/0
3-3/0
3-4/0
3-3/0
3-4/0
3-4/0
3-4/0
3-4/0
4-4/0
3-4/0
4-4/0
4-4/0
4-3/0
4-4/0
4-4/0
OM-2221 Page 13
400 ft
(120 m)
1/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
3-4/0
4-4/0
4-4/0
S-0007-E