Specification
Cooling Method
Overall Dimensions
Cable Length
Plasma Gas
Plasma Gas Flow/Pressure
Ampere Rating
Cutting Capacity
Gear Rack Pitch
(Machine Torches Only)
Weight
Hand-Held
Torch
A
B
SECTION 2 – SPECIFICATIONS
Table 2-1. Cutting Torch
Air
See Figure 2-1
30 Or 50 ft (9.1 Or 15.2 m)
Air Or Nitrogen
ICE-50
4.7 CFM (135 L/min) At 60 PSI (413
kPa)
Low Range: 35 Amperes At 100%
Duty Cycle; High Range: 55 Am-
peres At 60% Duty Cycle (See
Section 2-1)
Up To 5/8 in (16 mm) Mild Steel And
Stainless; Up To 3/8 in (10 mm)
Aluminum
Not Applicable
Net: 13-1/2 lb (6.1 kg)
C
D
Figure 2-1. Overall Dimensions
Description
ICE-70 And 70M
7 CFM (198 L/min) At 70 PSI
(483 kPa)
70 Amperes At 100% Duty Cycle
(See Section 2-1)
1 in (25 mm) Mild Steel, Stainless,
And Aluminum
32
Net: 10-1/2 lb (4.7 kg)
Machine-Held
Torch
E
F
50 ampere model is available
as hand-held only.
ICE-100 And 100M
7 CFM (198 L/min) At 70 PSI
(483 kPa)
100 Amperes At 80% Duty Cycle
(See Section 2-1)
1-1/4 in (32 mm) Mild Steel,
Stainless, And Aluminum
32
Net: 10-1/2 lb (4.7 kg)
Inches
Millimeters
A
10
254
B
1-1/8
29
C
2-1/4
57
D
1-3/16
30
E
1-3/8
35
F
14-3/8
365
ST-800 712-A
OM-1591 Page 5