3-5. XT40 Torch Specifications
Torch −
The XT40 torch is intended for handheld use only. The torch conforms to IEC 60974-7 when used with the Spectrum 625
X-TREME. Do not use this torch in combination with any other machines.
Gas Type
Gas Quality
Gas Inlet Flow and Pressure
Gas Filtering
Cooling Method
Duty Cycle of Torch
Rating of Electrical Controls (Trigger)
Rating of Electrical Controls (Cup)
Approved Systems
Trigger Protection
Safety Devices
Rated Capacity (edge start)
Sever Cut Capacity (edge start)
Pierce Capacity
*Travel speeds are approximately 80% of maximum.
Weight
Requirements for the torch connection
S
Use only compressed air which is free from dirt, oil, and water.
S
Ensure that the connections are properly assigned and tightened.
S
For torch replacement, see Miller torch manual Part No. OM-254449
S
Ensure correct air pressure (flow pressure) and airflow (volume) are set. Insufficient airflow can lead to the torch overheating.
3-6. XT40 Torch Dimensions
OM-254 449 Page 12
Spectrum 625 X-TREME w/XT40 torch
Safety interlock devices shut down power source
1-3/16 in.
(30 mm)
Air or Nitrogen
Clean, moisture−free,
oil−free
6.0 SCFM (170 L/min)
Particulates to 5 microns
Air
100% at 40 Amps
30 VDC at .1 Amps
30 VDC at 1 Amp
Safety trigger guard
5/8 in. at 13 ipm (330 mm/min)*
7/8 in. at 4 ipm (102 mm/min)*
5/16 in.
2.5 lb (1.1 kg) 12 ft (3.7 m)
3.4 lb (1.5 kg) 20 ft (6.1 m)
8-3/4 in.
(222 mm)
1-1/2 in.
(38 mm)
−−
−−
−−
−−
90 PSI (621 kPa)
120 PSI (827
Min
kPa) Max
−−
−−
−−
−−
−−
−−
− −
− −
− −
− −
−−
−−
−−
−−
−−
−−
− −
− −
Ref. 253 554-A