Installation and Maintenance
Please switched off the electrical power when you clean the inside or change the UV-
C lamp. When clean the inside or change the UV-C lamp, please take below part list
as your reference.

Installation

After assembling the fountain parts according to the structure diagram, adjust the
extension tube to the appropriate height and immerse the equipment und er the
water. If you need to pump clean water, you can remove the fountain assembly and
install the water outlet pipe for using.
Maintenance for filter sponge and filter material
1.
Take of the fountain parts, and open the two clips on the side of the filter
cover, then you can open the filter cover.
2.
Take out the filter sponge and filter material(boxes), clean or change
these.(suggest to clean the filter sponge every week)
Maintenance for UV-lamp
1.
Open the pump, remove the UV-C lamp from the pump, open the safety
buckle, and rotate the lamp head counterclockwise to remove the quartz glass tube
assembly. At this time, the UV-C lamp can be replaced (the CUF-3800 series does
not need to open the pump, rotate the lamp head directly counterclockwise to
remove).
2.
If you want to clean the quartz glass tube, remove the fixing nut and take it out
for cleaning.
Maintenance for Water Pump
1.
Rotate the impeller cover counterclockwise to the stuck position and open it
outward to separate the impeller cover from the pump body.
2.
Remove the rotor and clean all parts with the small brush.
Storage in winter
1.
Take out the equipment from water.
2.
Clean the equipment thoroughly.
3.
Check the parts and conditions of the equipment.
4.
Keep this equipment in a area that free from frost. And in a container that with
clean water.
Easily broken parts
1.
UV-C lamp.
2.
Filter materials (bio-ball, gravel, filter sponge).