System Limitations
• Chlorine or other strong oxidizers will
damage the filter media bed
of these systems and should
never be used.
• The FE & RE Edition utilizes air,
oxidation and filtration for the removal
of Iron and Sulfur. This process will
leave some air or effervescence in the
water. The effervescence may give the
water a milky appearance and is
Regeneration Cycle (59 minutes)
1. Backwash (14 minutes)
During this cycle, the water carrying the iron runs to the drain. Untreated water is
available during regeneration.
2. Air Recharge (40 minutes)
During this cycle, the unit empties the water to the drain and is recharged with
air, oxidizing the media. The sound of air being recharged will be heard. Air
bubbles should go down to the drain before proceeding to the next step. Adjust
cycle time if necessary.
3. Rapid Rinse (1 minute or Off)
During this cycle, water enters the tank, compressing the air into a pocket at the
top of the tank.
simply excess air in the water. While a certain
amount of effervescence will always be present,
it may be most noticeable during the first 30 days
after installation of the system.