Malfunction Table
Malfunction
Collection bowl fills too
slowly or does not fill at all
Collection bowl is full, but the
water continues to flow into
the drainage
No water drainage
Reason
Water preparation unit
cartridges have clogged
Membrane element in the
membrane cartridge has clogged
Faulty membrane valve
Connection assembly valve
is closed
Low inlet pressure
A foreign object in one of the
lead tubes
Faulty automatic valve
Water preparation unit
cartridges have clogged
Membrane element of the
membrane cartridge has clogged
Restrictor (drainage flow
restrictor) has clogged
Elimination method
Water preparation unit
cartridge replacement
Replacement of the membrane
element
Contact the customer service
Open the connection assembly
valve
Installation of boost pump for
the whole apartment or
separately for the filter
Contact the customer service
Contact the customer service
Water preparation unit
cartridge replacement
Replacement of the membrane
element
Contact the customer service
Appendix