1.4 Install Vents
Image 12: B80 MOTHERSHIP with 1U vents above and below for proper airflow.
Important Installation Notes:
1.
Install the 1U vents above and below the B80 chassis. The MOTHERSHIP MUST run
with proper ventilation.
2.
The BP300 power supply should be installed underneath the MOTHERSHIP rather than
above it.
3.
Failure to properly vent the MOTHERSHIP chassis above and below may cause failure,
and will void the warranty.
1.5 Connect Digilink Port 1 to Core Card
Each Digilink Port on the BMB1 can run up to 32 ins/outs.
If you have 32 I/O or less, you only need to use port 1.
If you have more than 32 I/O, use ports 1 and 2.
Both Ports on the BMB1 are primary ports.
1.6 Set BMB1 Front Panel to DAW for use with Pro Tools
When using B80 internal clock, set the CLOCK CONTROL to DAW, which
allows Pro Tools to change sample rate.
If using external clock, set to EXT.
B80-BMB1
5