DCM Melangers with Pneumatic Pressure System have the following additional parts:
● Two Support Spacers between the top bar and the base of the vertical tension control threaded
rod.
● Air Cylinder centered above the top bar to provide tension force.
● Pressure Regulator comprising the tension control valve, pressure gauge, and the air filter.
● Compressed air source must supply clean dry air with a minimum of 80 pounds per square inch
(5.5 bar) and 0.1 cubic feet per minute (2.8 liters per minute).
● Intake Air Tube ( Connected to the factory pressure supply or Air Compressor).
● Regulator air tube is connected to the Air cylinder.
The Support Spacers are located on the threaded rod of the Frame Arms. The top bar is located on the
threaded rods of the frame arms (above the support spacers). Be sure the slot in the top bar tensioner is
engaged with the flat portion of the vertical bar of the roller stone holder. Rotate both tension control
knobs evenly until they lock in place firmly securing the top bar. All tension is controlled by the air
cylinder. The tension control knobs should not be used for tension control in this application. They must
be tightened fully. Connect the air line to your compressed air source. Use the pressure adjustment
knob to adjust the starting air pressure to 10 psi or less as read on the pressure gauge. Use the pressure
adjustment knob and gauge to set the stone tension as required by your process. The pressure must
never be set above 60 psi as this will apply excessive pressure on the stones which will result in
premature wear or other damage that is not covered by the warranty.
The following procedure should be used for disassembling.
1 .​
R emove the air pressure by disconnecting the supply line and the electrical power line.
2 .​
R emove the air line from the air cylinder by pulling back on the quick disconnect sleeve.