Chronomite CMT-4.0 설치 및 작동 지침 매뉴얼 - 페이지 6

{카테고리_이름} Chronomite CMT-4.0에 대한 설치 및 작동 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Chronomite CMT-4.0 16 페이지. Electric mini tank water heaters

INSTALLATION INSTRUCTIONS

FOR CMT-1.3/CMT-2.5/CMT-4.0/CMT-6.0
The installation must be completed by a licensed professional. All state and local codes must be
adhered to. The manufacturer will not be liable for any damages because of failure to comply with these
installation instructions or because of improper installation performed by an unqualified installer.
Choose a location that allows ease of access for maintenance or servicing, ideally installed at
least 8" to 9" from the ceiling (inside top of cabinet) or any adjacent walls.
Wall Mounting
Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall material and
the weight of the water heater filled to capacity (CMT-1.3 = 24 lbs CMT-2.5 = 41 lbs, CMT-4.0 = 57 lbs
and CMT-6.0 = 76 lbs). Hang the water heater on the bracket and pull downwards on the water heater
to insure that both "fingers" of the bracket are seated in the mounting slots. Confirm your water piping
orientation (hot and cold) before wall mounting. Only install in vertical position.
Heater can sit on the floor. Confirm water piping orientation before finalizing on floor. Again, only install
in vertical position! CMT models can also be installed under the sink.

Plumbing Connections

Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet
pipe to the outlet nipple (marked with a red ring).
Important:
If Water pipes are copper or bronze, use dielectric connections to prevent corrosion. Failure
to provide dielectric insulation may result in premature tank or nipple failure and may void your
warranty. Insure that the water heater is installed in a level position. Install a shut off valve on the cold
water side of the water heater. The valve is for servicing and the valve should be in the open position
when the water heater is in operation. In order to protect the water heater from heat damage due to
soldering, solder a piece of tubing to a threaded union fitting before screwing the union to the tank. Do
not apply heat directly to inlet or outlet connections.
3100-010-001
10/17 REV 1
ELECTRIC TANK WATER HEATER - POINT OF USE
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 6 of 16
Chronomite Laboratories is a Member of Morris Group International™
CHRONOMITE TECHNICAL SUPPORT