Temperature Adjustment Potentiometer - (L) and (S) Activation Models
The potentiometer allows the factory preset temperature of the heater to be changed in the field. The
potentiometer will adjust water temperature between 70°F and 140°F provided the wattage of the heater selected
is capable of producing the temperature increase at the requested flow rate. See Table 3 temperature chart for
each model to determine the temperature range of the heater installed.
When using the potentiometer please use the following operation instructions:
To increase temperature:
a. Loosen nut
b. Using a screwdriver, turn screw in small increments clockwise (to the right)
c. Once temperature of the water is acquired, tighten the nut
To decrease water temperature:
a. Loosen nut
b. Using a screwdriver, turn screw in small increments counter clockwise (to the left)
c. Once temperature is acquired, tighten the nut
Temperature Adjustment - (H) Activation Models
The H model is factory preset for 84°F only and is designed for tepid water use. See Table 3 temperature chart for
each model to determine the temperature range of the heater installed.
Model
ER-90x/208_3P
ER-90x/240_3P
ER-120x/208_3P
ER-120x/240_3P
Microprocessor limits temperature increase according to the pre-selected outlet temperature
x = (L)-Low Activation
(S)-Standard Activation
(H)-High Activation
TABLE 3 – Temperature Rise Chart
Wattage
3Φ Voltage
18,700
208
21,600
240
24,960
208
28,800
240
°F Temp Rise @
3.25 GPM
39
45
52
61
°F Temp Rise @
4.25 GPM
30
35
40
46
6 |