First cleaning
Clean the device before the first use. (See 6 Cleaning)
Gas connection
The appliances run on the following gases: Butane G30, Propane G31, Natural gas
G20/G25. The appliances are originally delivered with a Butane/Propane injector
(85/100 for SGM 600, 100/100 for SGM 800 and SGF 800) corresponding to the cate-
gory II2E+3+, under pressure of 28/30/37mbar. The connection is made thanks to a
thread G 1/2.
The heat release rate of the appliance is
- SGM 600
5,3 kW
- SGM 800
8.1 kW
- SGF 800
8,1 kW
Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.
The fresh air flow required for combustion air supply is:
- SGM 600
10m3/h
- SGM 800
15m3/H
- SGF 800
15 m3/H
General conditions of installation
The installation and maintenance of the appliance must be carried out in compliance
with the statutory texts and good practices in force, mainly:
General specifications
For all appliances:
Article GZ Installation with combustible gases and liquefied hydrocarbons.
Then, according to use:
Article CH Heating, ventilation, refrigeration
Air conditioning and domestic hot water steam generation.
Article GC Installation of appliances to be used for catering
Specific provisions for each type of establishment to which the public is admitted
(hospitals, shops, etc...)
Important: Never change the diameter of the injectors.