4.7 - Maintenance
In order to ensure long life and correct operation of the refrigeration system, regular maintenance of the condensation should be
carried out, as follows:
Disconnect the cupboard from the electric current, by taking out the plug.
Vacuum or lightly brush the condensation, according to the track direction.
4.8 - Prolonged lack of Use
When prolonged periods with lack of use are predicted, the following measures are recommended:
Disconnect the cupboard from the electric current;
Remove completely the food produce;
Carry out any maintenance operations;
Leave the doors slightly open so to avoid odours.
4.9 - Irregularities
Should any irregularities in the operation be detected, before calling the technical services, ensure that:
The main switch is lit;
The doors/drawers close correctly;
The equipment is not placed near to any heat source;
The condenser is clean and the ventilator motor is operational;
There is not too much ice in the evaporator.
Should these inspections be negative, it is advisable to remove what is placed within the cupboard, disconnect it from the
electricity network and request assistance from the nearest technical services available.
Note: Maintenance should be carried out by specialised technicians and the use of non-original parts allow that the manufacturer
withdraws any responsibility and cancels the guarantee.