TROUBLESHOOTING

It is not recommended that the end user attempt to perform repairs on this tool, as specialized tools, training, and/or
procedures may be required.
Should you have any problems or questions with your BURNDY
the BURNDY
Customer and Technical Service Departments by calling 1-800-346-4175, or the BURNDY
®
Center for tool servicing and repair related questions at 1-800-426-8720; [email protected].
TROUBLESHOOTING GUIDE
SYMPTOM / PROBLEM
Jaws do not close when
activation trigger is pressed.
Jaws do not fully close.
Excessive or unusual noise
from tool.
Oil leaks from tool.
Number of crimps/cuts per
charge decreases with each
battery recharge.
Tool will not stop running after
activation trigger is released.
Jaws/blades do not retract with
the ram when the black retraction
trigger is depressed.
(PATMDCUTLW only)
Audible "pop" is heard before
cable is cut or crimped.
When installing new jaws, the pin
does not line up with the hole
For further assistance, contact the BURNDY
CAUSE
- Battery is not charged.
- Ram release trigger/valve is being
held open.
- Pump is damaged.
- Activation trigger switch failure.
- Hydraulic system failure.
- Mechanical vibrations.
- Cavitation due to cold hydraulic fluid.
- Cavitation due to hot hydraulic fluid.
- Seal defect or mechanical problems.
- Battery is too warm due to frequent
discharge/recharge cycling.
- Activation trigger stuck.
- Switch failure.
- Chip is caught between blades or
there is another interference in the
blade or guide area.
- Cable is larger or a harder material
than is recommended.
- Blades are dull or chipped.
- Pressure relief valve setting is set
too low.
- Ram is not fully retracted.
®
hydraulic tooling, please do not hesitate to contact
®
- Charge the battery according to the Battery
Charger Instruction Manual provided with
your tool.
- Press and release the ram release trigger to
reset the valve.
- Return to factory for repair.
- Return to factory for repair.
- Return to factory for repair.
- Return to factory for repair.
- Allow tool to warm up before use.
- Allow tool to cool before continuing use.
- Return to factory for repair.
- Allow battery to cool to room
temperature before recharging.
- Alternate batteries often.
- Remove battery and check for contaminants
around the trigger switch area.
- Remove battery and return to factory for
repair.
- See OPERATION INSTRUCTIONS section and
follow the instructions in the note.
- If cutting less than 6 inches from the end of
the cable, wrap cable with tape, and cut on
the taped area.
- See SPECIFICATIONS section and only cut
within the tool's cutting capacity.
- Replace blades.
- Return to factory to have the valve setting
increased.
- Press the black retraction trigger to retract the
ram fully OR
- Squeeze jaws further than normal to line up the
pin with the hole in the jaws.
Tool Service Center at 1-800-426-8720.