2-1-1. Zoom center Adjustment
1. Select "CAM(C)" section after start up the PC EVR software, and click "OK" button.
2. Select "Adjustment Tool" in "Tools(W)" menu, Adjustment Tool screen will appear on screen.
3. Make the zoom position Tele terminal by pressing Zoom lever.
4. Click "T READ" button on the Adjustment Tool screen.
5. Make the zoom position Wide terminal by pressing Zoom lever.
6. Click "W READ" button on the Adjustment Tool screen.
7. Repeat the operation from step 3 to 6 three times.
8. Clicking "Set" button as follows on the Adjustment Tool screen, the adjusted value is saved in EEPROM.
9. When the adjustment is completed, the following message screen is displayed. Turn the power of camera
recorder to OFF and clicking "OK" button, PC EVR software closes compulsorily.
2-1-2. Hall Amp / Iris PWM / OIS Hall Amp Adjustment
1. Select "CAM(C)" section after start up the PC EVR software, and click "OK" button.
2. Select "Adjustment Tool" in "Tools(W)" menu, Adjustment Tool screen will appear on screen.
3. Clicking the "Execute" button, the adjustment is executed automatically.
4. When the adjustment is completed, the message "Adjustment OK!" is displayed in the STATUS column on
the Adjustment Tool screen and the following message screen is displayed. Clicking "OK" button, power is
turned OFF and ON automatically and PC EVR software closes compulsorily.
ELE-9