AquaScape 99445 설치 및 유지 관리 지침 매뉴얼 - 페이지 8
{카테고리_이름} AquaScape 99445에 대한 설치 및 유지 관리 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AquaScape 99445 16 페이지. Solids handling pump
7) Troubleshooting
7.1 Pump is not operating
• Ensure pump is plugged into a properly grounded and operational outlet. Outlet should
be GFI protected. Ensure that the GFI outlet has not reset due to ambient moisture. Press
"Test" and then "Reset" on the GFI outlet.
• Ensure Solids Handling Impeller is able to move freely. The impeller should be able
to move with some effort inside the pump housing. If it is jammed with debris, follow
instructions under Routine Maintenance to expose and check the Impeller.
7.2 Reduced flow from pump
• Ensure that the Upper Pump Housing and the Lower Pump Housing is free of
leaves and debris.
• Check pipe and plumbing for any possible kinks or blockages.