(Ex. 20). Removing scale build-up will allow your pump to
run like new again.
Replacing the Impeller/Rotor Assembly
• For Model 3600 and
5200: When replacing the
AquaForce 3600 or 5200
rotor-impeller assembly into
the pump chamber, note
the proper orientation. The
raised key on the impeller
face plate should be lined
up with the groove in the
pump housing (Ex. 21).
• For Models 1000, 1800 and 2700: The 1000, 1800 and
the 2700 models allow the impeller-rotor assembly to be
inserted into the pump body with no special alignment
guides needed (Ex. 22).
Winter Application
If running through winter conditions, check regularly to make sure it is functioning properly and ice is not preventing water
from reaching the pump. In the event of a power failure, the pump should be removed to prevent any freeze damage to the
pump or the piping.
If concerned about possible freeze damage, disconnect and remove the pump. Be careful not to lose the flat rubber washer.
Clean with fresh water and store the pump in a frost-free location. If needed, use Aquascape Pump Cleaner Maintenance
Solution (#91143) to remove excessive buildup.
Troubleshooting
• Reduced water flow
– Pump or plumbing may be clogged. It may be necessary to clean the pump cage screens and impeller.
• Pump hums but doesn't push water
– The pump or plumbing may be clogged.
It may be necessary to clean the pump cage screens and impeller.
Remove the water chamber cover and inspect and clean the impeller rotor assembly and internal pump body.
Make sure nothing is blocking or wrapped around the impeller.
– Make sure the pump is receiving the correct voltage.
• Pump not working
– The ground-fault circuit interrupter (GFCI) may have tripped.
– The pump is not receiving the correct voltage.
☎
aquascapeinc.com |
CAN (866) 766-3426 |
• AquaForce 5200 ready for reassembly: The water
Ex. 20
chamber cover will only fit back onto the pump with the
top of the tear-drop shapes lining up, along with matching
the hole in the cover with the pin on the face of the pump
motor flange (Ex. 23).
Groove
Raised key
Ex. 21
Replacing Pump in Cage
• Replace the pump into the lower cage and secure in place
with the brackets. Also replace the power cord in the
strain relief.
• Reinstall filter cage and close all 5 clips.
☎
US (866) 877-6637
Pump
flange pin
Pump
flange pin
Pump water
cover hole
Ex. 22
Pump water
cover hole
Ex. 23
7