• Install second outer bearing washer over the impeller shaft
(Ex. 22).
• Replace water chamber cover containing the impeller shaft
centering bushing by sliding it over the impeller shaft and
then rotating it clockwise to lock it into place over the tabs
on the pump housing (Ex. 23).
Ex. 22

Winter Application

If concerned about possible freeze damage, disconnect the pump and remove the pump from the water. Clean the pump
with fresh water and store the pump in a frost-free location. The pump can be run during cold weather, if desired, but should
be removed in the event of a power failure to prevent any freeze damage to either the pump or the tubing.

Troubleshooting

• Reduced water flow
– It may be necessary to clean the filter screen, sponge, and impeller.
• Pump hums but doesn't push water
– It may be necessary to clean the filter screen, sponge, and impeller.
– Remove the water chamber cover and inspect and clean the impeller rotor assembly and internal pump body.
– Make sure nothing is blocking or wrapped around the impeller.
– Make sure the pump is receiving the correct voltage.
• Pump not working
– The ground-fault circuit-interrupter (GFCI) may have tripped.
– The pump is not receiving the correct voltage.
aquascapeinc.com |
CAN (866) 766-3426 |
• Replace the pre-filter
sponge and filter screen
before operating the pump.
Using the pump without
filter screens or sponge may
damage the pump and will
void the warranty (Ex. 24).
Ex. 21
Ex. 23
US (866) 877-6637
Ex. 24
7