Diamond 60/40 PCG-D Series 설치 - 사용 - 유지 관리 - 페이지 8

{카테고리_이름} Diamond 60/40 PCG-D Series에 대한 설치 - 사용 - 유지 관리을 온라인으로 검색하거나 PDF를 다운로드하세요. Diamond 60/40 PCG-D Series 19 페이지. Range, gas solid top

REPLACING THE NOZZLE AND THE MAIN BURNER
PRIMARY AIR REGULATION
Remove the control panel.
Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
Slacken screw V and position the air regulator at
distance A as indicated in table TAB1.
Retighten screw V fully.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE MINIMUM ADJUSTMENT SCREW
Remove the control panel.
Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE PILOT BURNER NOZZLE
Remove the control panel and internal guards.
Undo connector R.
Remove nozzle UP and replace it with the one
indicated in table TAB1.
Retighten connector R. Reassemble all parts.
Following, in reverse order, the sequence used for
their removal.
GAS OVEN
REPLACING THE NOZZLE AND THE MAIN BURNER
PRIMARY AIR REGULATION
Open the oven door.
remove the sole and the protection panel
Slacken screw V.
remove the UM nozzle.
Retighten nozzle UM.
Place the aeration adjuster at the distance A
specified in the table TAB1.
Retighten screw V fully.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE MINIMUM ADJUSTMENT SCREW
Remove the control panel.
Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
Reassemble all parts. For assembly, proceed in
reverse order.
GAS STOCKPOT STOVE
REPLACING THE NOZZLE AND THE MAIN BURNER
PRIMARY AIR REGULATION
Remove the control panel.
Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
Slacken screw V and position the air regulator at
distance A as indicated in table TAB1.
Retighten screw V fully.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE MINIMUM ADJUSTMENT SCREW
Remove the control panel.
Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE PILOT BURNER NOZZLE
Remove the control panel.
Undo connector R.
Remove nozzle UP and replace it with the one
indicated in table TAB1.
Retighten connector R. Reassemble all parts.
Following, in reverse order, the sequence used for
their removal.

9. COMMISSIONING

Following installation, conversion to a different
type of gas or any maintenance operations, check
appliance operation. In the event of any
malfunction, consult the next Paragraph "
Troubleshooting " .
GAS APPLIANCES
Switch on the appliance as directed in the
instructions and reminders for use given in
10