AquaScape 91104 지침 및 유지 관리 - 페이지 7
{카테고리_이름} AquaScape 91104에 대한 지침 및 유지 관리을 온라인으로 검색하거나 PDF를 다운로드하세요. AquaScape 91104 20 페이지. Adjustable flow solids-handling pond pump
AquaScape 91104에 대해서도 마찬가지입니다: 교육 및 유지 관리 (9 페이지), 교육 및 유지 관리 (16 페이지)
NOTE: Do not remove the cage while operating the pump,
as failure to do so may cause the pump to fail, voiding the
warranty.
• Pull the cage release tabs outward to unlock the cage
(Ex. 17), then lift the upper cage to expose the pump
(Ex. 18).
• Remove the screws securing the pump to allow the pump
to be lifted from the lower cage.
• Remove the four screws on the pump to disconnect the
water chamber cover (Ex. 19).
☎
aquascapeinc.com |
CAN (866) 766-3426 |
NOTE: For easier pump access, pull the power cord free
from the strain relief (Ex. 20).
• Remove the impeller by pulling gently (Ex. 21).
• Clean the impeller and internal pump body with
Ex. 17
Aquascape Pump Cleaner Maintenance Solution (#91143),
using a sponge or soft-bristle brush.
• Re-install the impeller,
making sure the assembly
is oriented correctly and the
raised key on the impeller
face plate is lined up with
the groove in the pump
housing (Ex. 22).
NOTE: Be sure to replace
the cage and verify the
cage is not broken before operating the pump, as failure to
do so may cause the pump to fail, voiding the warranty.
Ex. 18
Ex. 19
☎
US (866) 877-6637
Ex. 20
Groove
Raised Key
Ex. 21
Ex. 22
7