• Remove the screws securing the pump to allow the pump
to be lifted from the lower cage.
• Remove the four screws on the pump to disconnect the
water chamber cover (Ex. 21).
NOTE: For easier pump access, pull the power cord free
from the strain relief (Ex. 22).
• Remove the impeller by pulling gently (Ex. 23)
Ex. 22
Winter Application
If running through winter conditions, check regularly to make sure it is functioning properly and ice is not preventing water
from reaching the pump. In the event of a power failure, the pump should be removed to prevent any freeze damage to the
pump or the piping.
If concerned about possible freeze damage, disconnect and remove the pump. Be careful not to lose the flat rubber washer.
Clean with fresh water and store the pump in a frost-free location. If needed, use Aquascape Pump Cleaner Maintenance
Solution (#91143) to remove excessive buildup.
Troubleshooting
• Reduced water flow
– The pump or plumbing may be clogged
Make sure nothing is blocking the intake
Clean the outer cage
Clean the impeller rotor assembly and internal pump
body
• Pump hums but doesn't push water
– The pump or plumbing may be clogged
Make sure nothing is blocking the intake
Clean the outer cage
Clean the impeller rotor assembly and internal pump
body
☎
aquascapeinc.com |
CAN (866) 766-3426 |
• Clean the impeller and internal pump body with
Aquascape Pump Cleaner Maintenance Solution (#91143),
using a sponge or soft-bristle brush.
• Re-install the impeller,
making sure the assembly
is oriented correctly and the
raised key on the impeller
face plate is lined up with
the groove in the pump
housing (Ex. 24).
NOTE: Be sure to replace
the cage and verify the
cage is not broken before operating the pump, as failure to
Ex. 21
do so may cause the pump to fail, voiding the warranty.
Ex. 23
– Make sure the pump is receiving the correct voltage
– Make sure the impeller blades are not worn or damaged
• Pump not working
– Ground-fault circuit interrupter (GFCI) may have tripped
– The pump is not receiving the correct voltage
• Device won't pair
– Make sure the outlet is receiving power
– Make sure you have adequate wireless coverage to
connect the device
– Reset the device to factory defaults
– Make sure the ground-fault circuit interrupter (GFCI) is
not tripped
☎
US (866) 877-6637
Groove
Raised Key
Ex. 24
7