Panasonic WV-NP304 설치 매뉴얼 - 페이지 25
{카테고리_이름} Panasonic WV-NP304에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Panasonic WV-NP304 36 페이지. Ip video cameras
Panasonic WV-NP304에 대해서도 마찬가지입니다: 브로셔 (2 페이지), 사용 설명서 (20 페이지), 사용 설명서 (20 페이지), 참조 (2 페이지), 비교 차트 (6 페이지), 설치 매뉴얼 (36 페이지), 사용 설명서 (20 페이지), 통합 참고 사항 (8 페이지)
• When using PoE (Power over Ethernet: IEEE802.3af compliant)
Connect a LAN cable (category 5 or better) between a PoE device (such as a PoE hub) and
the network connector of the camera.
Important:
• Use all of 4 pairs (8 pins) of the LAN cable.
• Maximum length of an Ethernet cable that can be connected is 100 m.
• Make sure that the PoE device in use is compliant with IEEE802.3af standard.
• When connecting both the 12 V DC power supply and the PoE device for power supply,
PoE will be used for power supply.
• When disconnecting the LAN cable once, connect the cable again after 2 seconds or
more from the disconnection. When the cable is connected before 2 seconds passed, the
power may not be supplied from the PoE device.
• Refer to the provided slip (Recommended network devices for PoE (IEEE802.3af compli-
ant) connection with the WV-NP304) for applicable PoE devices.
v
Connect a LAN cable (category 5 or better)
to the network connector on the rear.
b
Connect an external device to the EXT connector.
Remove 9 mm - 10 mm of the outer jacket of the cable from the
external device and twist the core of the cable to prevent a short cir-
cuit.
Specification of cord (wire): AWG #22 - #28 single core, twisted
* Make sure that the exposed core wires are completely hidden
after inserting the cable.
Important:
• Do not connect 2 wires or more directly to a termi-
nal. When it is necessary to connect 2 wires or
more, use a splitter.
• Connect an external device with verifying that the
ratings are within the specification below.
<Ratings>
q GND
w AUX OUT
Output specification: Open collector output (Maximum applied voltage: 20 V DC)
Open: 4 - 5 V DC by internal pull-up
Close: Output voltage of 1 V DC or less (50 mA or less)
e ALARM OUT
Same as AUX OUT
r ALARM IN
Input specification: Non-voltage make contact (4 - 5 V DC internal pull-up)
OFF: Open or 4 - 5 V DC
ON: Make contact with GND (drive current: 1 mA or more)
100BASE-T/
FOCUS
LINK
100BASE-TX
ACT
ASSIST
POWER
SD
CARD
AUDIO OUT
MIC IN
MONITOR OUT
EXT I/O
12V
IN
24V
IN
C B A
1 2 3 4
Approx. 9 mm - 10 mm
q GND
w AUX OUT
(AUX output terminal)
1 2 3 4
r ALARM IN (Alarm input terminal)
e ALARM OUT
(Alarm output terminal)
Ethernet cable
Cut
25