Clock Adjustment (Sb)

Preparation:
Connect the frequency counter from TPS1 (IC001
Pin 13) to cold ground (
Note: Frequency Counter probe capacitance should
be 8pF or less.
Procedure:
1. Turn
the
Receiver
power applied.
2. Measure TPS1 (IC001 pin 13) for the frequency of
the waveform and record the reading.
Note: Pin 13 measurement must have at least four
digits of resolution following the decimal point.
Example: 000.0000
3. Turn the Receiver back "ON".
4. Place the Receiver into Service Mode for making
electronic adjustment, select the Clock Adjustment
DAC (Sb).

Service Adjustments (Mechanical Controls)

VCO Field Alignment L105
1. Connect a balance antenna and select a midband
channel (Ch 10, 11 or 12)
2. Attenuate the signal strength for a weak noisy
video.
3. While observing the picture tube, adjust L105 until
best picture appears.
4. Change channels and observe that they are tuning
properly.
5. If the channel monitored is not clear, repeat steps
1, 3 and 4 while applying a stronger signal.

Focus (part of T551)

Preparation:
Connect a Signal generator and select a do tpattern.
Procedure:
Adjust the FOCUS control to obtain the sharpest and
clearest dot pattern.
a. Adjust for best center.
b. Adjust for best area between the center and top
right corner.

E-W Pincushion

Perform H-Centering adjustment to confirm correct
picture centering.
Preparation:
Apply a crosshatch pattern.
Procedure:
Adjust E-W Pincushion by adjusting R761 on Z-Board
until outside vertical lines are as straight as possible.
).
"OFF"
with
the
AC
(IC101 pins 35 & 36)
5. Calculate
and
following formula:
Sb
=
128
+
0.901
Note: Pin
13
measurement
regardless of the value stored in Sb.
Vertical Size (B7)
1. Adjust the VERTICAL SIZE DAC control, B7, until
the top and the bottom edges of the raster are
visible.
2. Adjust the VERTICAL SIZE control, B7, until the
top and the bottom of the raster touch the bezel
edge. The advance SIZE control to obtain an
approximately 10% overscan. Linearity adjustment
is done automatically when the size is being
adjusted. (Best results can de obtained with a
round test patter.)
H- Width Adjustment
Perform H-Centering adjustment to confirm correct
picture centering.
Preparation:
Apply a monoscope pattern.
Procedure:
Adjust R760 and B7 until obtain a perfect round pattern
on the screen.
R760
- 24 -
set
Sb
based
on
{
[
6
244.1406 pin 13 Hz
×10
----------------------------------------------------------------- -
244.1406
will
not
R761
Z-BOARD
the
]
}
change