Panasonic CT-32HC14J 서비스 매뉴얼 - 페이지 4

{카테고리_이름} Panasonic CT-32HC14J에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Panasonic CT-32HC14J 47 페이지.

Panasonic CT-32HC14J 서비스 매뉴얼

12 Chassis service adjustment procedures

TOP PREVIOUS NEXT
All service adjustments are factory preset and should not require adjustment unless controls and/or
associated components are replaced.
140.0_V B+ voltage check
1. Set the BRIGHT and PICTURE to minimum by using the PICTURE menu.
2. Connect the DVM on TPD144 (D-Board by D2 connector) and cold ground
3. Confirm that B+ voltage is 144.0V ± 1.5V. This voltage supplies B+ to the horizontal output
and flyback circuits.
Source voltage chart
120V AC line input. Set the BRIGHT and the PICTURE to minimum by using the PICTURE menu.
Use cold or hot ground for the (-) lead of the DVM as needed
A-BOARD
STBY 7V (BY IC804) A-Board TPP9
MAIN 9V (BY IC875) A-Board TPA7
MAIN 5V (BY IC871) A-Board TPA8
GC 2.5V (BY IC872) A-Board TPA9
STBY 3.3V (BY A1 CONNECTOR) A-Board TPA16 3.3V ± 0.2V
D-BOARD
+B2 (BY D2 CONNECTOR) D-Board TPD144
25V (BY D40 CONNECTOR) D-Board TPD250
15V (BY D4 CONNECTOR) D-Board TPD150
http://schema99.host.sk/
VOLTAGE
7.5 ± 0.6V
9.0V ± 0.5V
5.0V ± 0.3V
2.5V ± 0.2
VOLTAGE
144.0 ± 1.5V
27.5 ± 2.0V
15.7 ± 1.5V