AquaStar Ultimate Ozone U3000 Kit 설치 및 사용자 설명서 - 페이지 4

{카테고리_이름} AquaStar Ultimate Ozone U3000 Kit에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AquaStar Ultimate Ozone U3000 Kit 6 페이지. Ozone generation system

Figure 2.1 Overview of System
General System Overview and Installation
The Ultimate Ozone™ system uses an air pump to move air through a corona discharge ozone generator. Our model
U1000 is capable of outputting 1 gram per hour of ozone which is suitable for treating up to 40,000 gallon pools.
Figure 2.3
Skimmer Ozone Ports
skimmer, the PVC pipe must be at least 2'4'' below water line and no greater than 4 feet, See Figure 2.3.
BLOW OUT OZONE TUBE TO CLEAR LINE OF WATER AND DEBRIS BEFORE ATTACHING OZONE DIF-
FUSER STONE.
Attach the ozone diffuser stone to the ozone compatible tubing and feed the diffuser stone into the 2" pipe (contact
chamber). The ozone diffuser stone should rest a minimum of three quarters of the way down the pipe. Secure the
bubble plate back into the throat of the skimmer by fastening both screws.
The contact chamber will allow water in through a returning fitting, (included with SKR1xx-OZ) that fits into 2" pipe
(33xx and BPxxx). Install the fitting housing so that it is flush with the pool's finish and thread in bubbler plate (BPxxx).
NOTE: THE THREAD IN BUBBLER PLATE IS NOT A SUCTION OUTLET AND DOES NOT NEED TO BE A
VGB COMPLIANT DRAIN TO COVER THE OPEN PIPE.
Ultimate Ozone™ Installation and User's Guide
Ozone is moved into the pool/spa through compatible 1/4'' tubing that is to be connected to
the 1/4'' Hose Barb Outlet Fitting on the bottom of the U1000 and connected to a FlowStar™
Ozone Compatible Skimmer (Aquastar Model # SKR1xx-OZ). (See Figure 2.2)
The ozone compatible tubing should be run inside 1'' conduit/PVC pipe; sweeps should be
used for any 90° turns. A junction box must be installed on the deck to avoid water back-
flow (AquaStar Model #JBRxxx or JBSxxx). Connect the conduit to the 1" port located at
the bottom of the junction box. Connect the ¼" ozone compatible tubing to the ¼" hose
barb located on the bottom of the ozone unit and feed the tubing through the conduit to the
junction box.
Another line of conduit should be run from the second 1" socket port located on the bot-
tom of the junction box to the 1" socket port located on the bottom of the Ozone compatible
FlowStar™ skimmer's throat. (See Figure 2.3). Remove the bubble plate, by unscrewing the
two screws located on either side, from inside the skimmer's throat and feed the ozone com-
patible tubing from the junction box to the skimmer.
Connect 2'' PVC pipe to the 2'' socket located on the bottom of the throat of the FlowStar™
Figure 2.2 Front View of System
3
Rev: 030717