Aquatec Aquapro AS10000DF 사용 설명서 - 페이지 6
{카테고리_이름} Aquatec Aquapro AS10000DF에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aquatec Aquapro AS10000DF 6 페이지. Submersible sump pump
tRoUBLEShootIng
Problem
The pump does not start, or
pump water
The pump does not supply water
when the motor is running
The pump flow rate is reduced
Pump will not turn off, even though
the water level is·low
Hose/tube does not stay on the
universal adaptor when water is
travelling through
The pump operates intermittently
Note: Please consult your retailer for quality original AQUAPRO replacement parts.
Visit www.aquatecequipment.com for nearest stockists. E.&O.E.
www.aquatecequipment.com
Possible Cause
Pump is not connected to the mains
power supply
Float switch has not been activated,
water level too low
The thermal overload protection
is activated
The motor is damaged
The suction base is obstructed/blocked
Air lock in the hose/tube and/or pump
(air bubbles)
Discharge hose/tube (not included) is
kinked or damaged
The suction base is partially
obstructed/blocked
The hose/tube is obstructed
Air leak in the suction line or joints
Incorrect assembly leads to air and
water leakage in the discharge lines
The float switch is stuck in the
"on" position
The hose/tube is slightly wider than the
dimension of the universal adaptor
The suction base is obstructed/blocked
Incorrect voltage is being used
The fluid contains particles thicker
than 5mm
The motor is faulty or damaged
The temperature of the fluid is too high
The water level is below 50mm
Solution
Check that the pump is connected to
the mains power supply
Manually raise the position of the
float switch
Wait for the motor to cool and it will
automatically start operation
Contact AQUAPRO customer service
Clean the suction base of any foreign
matter and debris
Perform several start-ups in order to
remove all the air or lift and tilt the pump
slightly while the pump is running
Un-kink the discharge hose/tube. Or
replace matter and debris
Clean the suction base of any foreign
matter and debris
Remove the obstructions
Check the suction line connections for
air leaks and tighten or fix where found
Ensure the discharge lines are the
correct length and all assembly
instructions are adhered to
Ensure that the float switch is free to
operate normally. Contact AQUAPRO
customer service if the problem
still occurs
An adhesive can be used inside the
hose/tube to prevent this or teflon
tape can be fixed around the universal
adopter or a hose clamp can be used
Clean the suction base of any foreign
matter and debris
Ensure the pump is connected into
240V power supply
Ensure the pump is not being used
with particles thicker than 5mm.
Contact AQUAPRO customer service
Ensure that maximum permissible water
temperature (35°C) is not exceeded
Ensure the water level is above 50mm