< Method of installing collimator (RFKZ0422) >
1. The collimator adapter is composed of the following parts.
Attachment ring
Adapter
Hex. Screw (A) X 4
Hex. Screw (B) X 2
2. Insert Collimator (RFKZ0422) in the adapter while expanding the space as shown in figure.
NOTE: Please expand the space when you remove the Collimator (RFKZ0422) from the adapter.
Space
Collimator
Adapter
3. Tighten the 4 hex. screws (A) and install the Attachment ring to adapter as shown in figure.
4. Tighten the 2 hex. screws (B) as shown in figure and the Collimator (RFKZ0422) is fixed to the Collimator
Adapter.
Hex. Screw (A) X 4
Hex. Screw (B)
Attachment ring
5. Set the Collimator (RFKZ0422) with the Collimator Adapter to the front of Lens as shown in figure.
(Light is applied to a collimator chart.)
Halogen lamp
ELE-12