How to install and connect the unit (continued)
When using the WV‑Q105A (optional accessory)
It is recommended that you provide an inspection opening or other such space for access purposes in the area near where the equipment is installed in
order to facilitate installation and the wiring connections work.
Before installation, check that the installation location is strong enough to withstand the total mass when the unit and HD integrated camera are
installed.
Use the mount bracket where the space between the ceiling panel and the concrete ceiling is at least 100 mm (3-15/16 inches) high.
The bracket can be mounted where the thickness of the ceiling panel ranges from 5 mm (3/16 inches) to 40 mm (1-9/16 inches).
The drop-prevention wire (supplied with the WV-Q105A) must be used when mounting the direct ceiling mount bracket.
Ceiling panel (plasterboard,
etc. with a thickness
from 5 mm (3/16 inches) to
40 mm (1‑9/16 inches))
1.
Refer to the Operating Instructions of the WV‑Q105A direct ceiling mount bracket, and attach the WV‑Q105A as well as the
drop‑prevention wire angle and drop‑prevention wire supplied with the WV‑Q105A to the anchor bolts.
Mounting the anchor bolts and direct ceiling mount bracket ()
This job is facilitated if the direct ceiling mount bracket is loosely secured to the ceiling panel in one place, and the direct ceiling mount bracket and
anchor bolts are vertically aligned before the nuts are tightened up.
2.
First, remove the screw which was loosely fastened in step 1, and then align mount bracket B of the AW‑HEA10 with the
screw holes in the WV‑Q105A direct ceiling mount bracket and mount it in place.
• Use the mounting screws (the M4-L60 Phillips head screws with adhesive) supplied with the WV-Q105A as the mounting screws.
• Fasten the AC adaptor securely to the bottom or other surface of the reinforcing member made of channel steel where dust and other foreign matter
will not accumulate.
• Do not place the AC adaptor directly onto the ceiling panel or other such surface.
Drop‑prevention wire
angle (supplied with
WV‑Q105A)
Drop‑prevention wire
(supplied with WV‑Q105A)
Inspection opening recommended
• The installation and wiring connection
work is facilitated if an inspection opening
is provided for access purposes.
Mounting screw x 4
(supplied with WV‑Q105A)
3.
Install the AW‑HEA10 camera by following the procedure starting with step 3 on page 10.
12
Concrete ceiling
Height above
ceiling panel:
At least 100 mm
(3‑15/16 inches)
Space above the ceiling
(): Fasten here using the nut.
Anchor bolts
AW‑HEA10
Anchor bolts
(Withdrawal strength: 294 N) (30 kgf) or more
The anchor bolts must not protrude
beneath the ceiling panel.
ø 60 mm
(2‑3/8 inches)
Direct ceiling mount bracket WV‑Q105A (optional accessory)
Plasterboard or other ceiling panel
Mount bracket B
(supplied with
AW‑HEA10)
(Ceiling
panel)
Channel steel
Secure the AC adaptor firmly to a