5. CONTROL VALVE INSTRUCTIONS continued

5.6.3. MANUAL REGENERATION

Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as a
manual regeneration. There may be a period of heavy water
usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, simultaneously press ▲
and ▼ and release. The arrow will point to the word Regen, if a regeneration is expected tonight.
To cancel the regeneration simultaneously press ▲ and ▼ and release.
To initiate a manual regeneration immediately, simultaneously press ▲ and ▼ for three seconds.
The system will begin to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours
before regenerating

5.6.4. SET TIME OF DAY

STEP 1U:
Press SET
STEP 2U:
Current time: Adjust hour with ▲ or ▼. With 60
Hz line frequency detection on power-up,
timekeeping is 12 hour with PM indicator. With
50 Hz line frequency detection on power-up,
timekeeping is 24 hour without the PM indicator.
Press SET to go to Step 3U.
Adjust minutes with ▲ or ▼. Press SET to exit
STEP 3U:
Set Time of Day.

5.6.5. POWER LOSS

Only the current time of day will need to be reset if power is
lost for greater than 8 hours. If power is lost while the system
is regenerating, the control will complete regeneration at the
point of interruption once power is restored.

5.6.6. ERROR MESSAGE

If "E1," "E2", "E3" or "E4" appears on the display contact
the OEM for help. This indicates that the valve did not
function properly.