5. CONTROL VALVE INSTRUCTIONS continued
Use the ▲ or ▼ buttons to switch between:
STEP 4SS:
• 1-99 Days
Regeneration is determined by the number of days that have passed since the last
regeneration scheduled.
• 7-Day
Regeneration is scheduled for specific days of the week.
Press SET to go to Step 5SS.
STEP 5SS:
If a differential pressure switch is installed and actuated for 2 minutes:
A regeneration will occur immediately if no arrow points at Regen Time; or
A regeneration will occur at the delayed regeneration hour if an arrow points at Regen Time.
Use ▲ or ▼ to switch between the two choices. If a differential switch is not installed the settings
in this display are ignored. Press SET to exit OEM system setup.
NOTE:
A regeneration will be initiated or
scheduled after the control has received
a signal for two minutes to the DP Input
(Item A).
A. Differential pressure switch connection
B. Motor wire connection
C. AC adapter wire connection
N1022 Quality Drive